Place of Origin: | CHINA |
Brand Name: | NANTE |
Certification: | CE |
Minimum Order Quantity: | 1pc |
---|---|
Packaging Details: | CARTON |
Delivery Time: | 1-2 weeks |
Payment Terms: | L/C, T/T |
Supply Ability: | 100000pcs per year |
Working Temperature: | -30℃ To +70℃ | IP Class: | IP55 |
---|---|---|---|
Material Of Control Box: | Cold Steel Or Stainless Steel | Cold Steel Or Stainless Steel: | 0.75kw To 30kw |
Main Power: | 220V,380V,415V,440V,460V | ||
Highlight: | overhead crane end trucks,bridge crane end trucks |
1. Summary
The electric control system consists of electric control box, electromagnetic braking motor and handle swithetc. The upward and downward movement of suspended platform is controlled by two electromagnetic braking motors.
2. Environmental Conditions
Suitable Altitude: 1000m ~ 4000m
Suitable Temperature: -30℃ ~ +70℃
Relative Humidity: Daily mean ≤95%, monthly mean ≤90%
Gradation of Earthquake Damage: ≤ Level 8
3. Technical Data
End Carriage Control Panel | |||
IP Class | IP55 | Contact Brand | Schneider |
Working Temperature | -30℃ to +70℃ | Relay Brand | Schneider |
Material of Control Box | Cold Steel or Stainless Steel | MCB Brand | Schneider |
Color of Box | Gray or Black | Main Power | 220V,380V,415V,440V,460V |
Inverter Capacity | 0.75kw to 30kw | Hertz | 50Hz or 60Hz |
Inverter Brand | YASKAWA,SCHNEIDER,DELTA | Control Power | 24V,36V,48V,110V,220V |
Suitable Crane | Under 20tons |
4. Overall & installation dimension
5. Product Feature
End Carriage Control Panel fixed AC metal enclosed switchgear (short for panel as below) is a new product designed and developed by NANTE MACHINERY, based on the introduction of advanced foreign design and manufacturing technology. It applies to 3.6~12kV three phase AC 50Hz single busbar or single busbar sectional transport, distribution system, as for receiving and distributing power energy, and realize to control, monitor and protect power circuit. It is widely used for power plant, substation, petroleum, metallurgy, chemical, natural gas and other civil field.
6. Structure feature:
1. END CARRIAGE CONTROL PANEL series is metal enclosed fixed switchgear, the body is welded with angle steel and steel board, inner and outer coating is solid by static spray plastic powder.
2. This panel conforms to GB3906 3-35kV AC Metal enclosed switchgear and international standard IEC62271-200 besides, prevent from opening and closing connecting switch with load, prevent from opening and closing circuit bre aker, prevent from entering into interval with electricity, prevent from closing earthing switch with electricity (five protections adopt simple, reliable mechanical interlock device). The power indicator is installed in front of panel which reflect voltage in the side of circuit. When circuit side with electricity, lock the enclosed board and panel door.
3. Same type product and structure component can exchange each other.
7. Enclosure
1 The inner structure of panel is divided into circuit breaker compartment, busbar compartment, cable compartment ,relay compartment, use steel plate to separate panels. Use eddy current steel plate and epoxy resin busbar bushing to separate panel.
2 The panel adopts cold roll steel sheet and angle steel to weld together, without reticulation fabric, non-flame-resisting materials. Outer insulating creeping distance of components and supporting insulator, pure porcelain insulation 1.8cm/kV, organic insulation 2.0cm/kV.The air distance of phase to phase, phase to earth 125mm. There is an intelligent hygrothermoscope to start or stop heater according to the humiture condition of circuit breaker compartment and cable compartment in panel, Prevent from forming moist and high temperature.
3 There is a viewing port for observing of closed and open position of upper, down connecting switch without open the door. The panel is double maintenance, inspect relay compartment equipments, operating mechanism, mechanical interlock and transmission part in front, inspect main busbar, shunt circuit busbar, cable terminal, connecting switch and earthing switch.
4 Circuit breaker: The circuit breaker is located in the middle part, disconnecting switch and earthing switch and interlock mechanism are above it, and with indicator device, describe open and closed position.
5 Transformer: CT is mounted on the underpart of front side, connect with circuit breaker and connecting switch, main loop without electricity. It can carry out preventive test, inspection and exchange, the secondary wire of CT to earth reliably .
6 Disconnect switch and earthing switch: connecting switch, disconnect switch and earthing switch can be seen t hrough viewing port, controlled by a set of manual operating mechanism to assure of program and reliable locking for circuit breaker, disconnect switch and earthing switch, meet the requirement of five protection.
7 Measuring instrument, relay protection, monitor device and auxiliary circuit .
8 Earthing: It takes a consideration of 440mm copper busbar as earthing body along with whole width of all panel extending.
Contact Person: Miss. Lexie. Mao
Tel: 86-15158039997 www.nantecrane.com
Fax: 86-575-85255335
Telecrane Wireless Hoist Remote Control Single Speed Fiberglass F21 Series
F21-E1 Radio Wireless Hoist Remote Controller Within 100m Control Distance
Crane Radio Remote Control Overhead Crane Controls For Beam Launcher
Single Speed Wireless Hoist Remote Control Fiberglass F24-12S ISO
Low Headroom Heavy Duty Motorized Stage Hoist High Wearable And Anti Corrosive
Hard Hook Electric Chain Hoist With 360 Degree Rotatable Safety
Construction Suspension Electric Chain Hoist Low Headroom 5 Ton 1~7.6m/min
Light And Durable Harrington Chain Hoist 3m To 130m Length Water Proof Push Button
Aluminum Distribution Insulated Ground Bar 4m 6m Standard Length 660V
Aluminium Copper Crane Conductor Bar Large Power Available Easy Installation
Current Collector Crane Bus Bar Monorail Systems Corrosion Resistance
Self - extinguishing Shell Crane Conductor Bar JDC 150-3000A CCC